They are the supporting components around a reader and controller: electric locks, exit push buttons, break-glass units, door closers, power supplies, backup batteries, RFID cards, key fobs and wristbands. Each part has a role in locking the door, letting people exit safely and keeping the system powered during outages.
Electromagnetic locks hold a door shut with a magnet and are rated by holding force, for example around 270 kg (600 lb). They release when power is cut, which is called fail-safe. Electric strikes and bolts suit wooden and metal doors and can be fail-safe or fail-secure. For fire exits, follow local fire safety rules that require doors to release in an emergency.
Locks and readers need a regulated DC power supply, commonly 12V or 24V. Add a battery backup so doors keep working during power cuts. Match the supply's current rating to the total draw of all locks and readers connected to it, and leave some spare capacity.